{"title":"Simulator","description":null,"products":[{"product_id":"rice-lake-ranger-1-variable-range-simulator-load-cell-indicator-tester","title":"Rice Lake Ranger 1 Variable Range Simulator Load Cell Indicator Tester","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eRice Lake Ranger 1 Variable Range Simulator\u003c\/strong\u003e\u003cspan\u003e is an economical and dependable load cell simulator designed for troubleshooting, testing, and verifying the performance of electronic weighing systems. It simulates the output of a load cell, allowing technicians to quickly diagnose issues with indicators, controllers, wiring, and scale systems without requiring actual scale loading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeaturing a continuously adjustable output from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 3 mV\/V\u003c\/strong\u003e, the Ranger 1 provides the flexibility needed for basic indicator testing and system verification. The large vernier adjustment knob and smooth 10-turn potentiometer allow precise output adjustments for stable and repeatable testing results.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe lightweight ABS enclosure weighs less than one pound, making it easy to carry in a service kit or toolbox. Its compact design is ideal for field technicians performing on-site diagnostics, preventive maintenance, and troubleshooting of industrial weighing equipment.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBinding post connections accommodate standard banana plugs or up to 14 AWG wire, allowing quick setup with a variety of scale indicators and instrumentation. The Ranger 1 is commonly used for bench testing indicator stability, simulating setpoints, verifying system response, and diagnosing load cell circuit issues.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhether servicing floor scales, bench scales, truck scales, hopper scales, or process weighing systems, the Ranger 1 provides a simple and reliable method for testing weighing electronics without the need for actual load cell inputs.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVariable output range from 0 to 3 mV\/V\u003c\/li\u003e\n\u003cli\u003eIdeal for load cell and indicator troubleshooting\u003c\/li\u003e\n\u003cli\u003eSmooth 10-turn potentiometer with large vernier adjustment knob\u003c\/li\u003e\n\u003cli\u003eBench test indicator stability and setpoint functions\u003c\/li\u003e\n\u003cli\u003eLightweight ABS plastic enclosure\u003c\/li\u003e\n\u003cli\u003eWeighs less than 1 lb for easy portability\u003c\/li\u003e\n\u003cli\u003eBinding posts accept banana plugs or 14 AWG wire\u003c\/li\u003e\n\u003cli\u003eEconomical solution for basic scale system testing\u003c\/li\u003e\n\u003cli\u003eDesigned for service technicians and scale calibration professionals\u003c\/li\u003e\n\u003cli\u003eOne-year limited manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRanger 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e68029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eVariable Range Load Cell Simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e700 Ohm Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotentiometer\u003c\/td\u003e\n\u003ctd\u003eSmooth 10-Turn Vernier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eBinding Posts for Banana Plugs or 14 AWG Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°F to 122°F (-18°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e±100 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5\" x 3.5\" x 1.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess Than 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne-Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScale Indicator Troubleshooting\u003c\/li\u003e\n\u003cli\u003eLoad Cell Testing\u003c\/li\u003e\n\u003cli\u003eBench Testing of Weight Indicators\u003c\/li\u003e\n\u003cli\u003eSetpoint Simulation\u003c\/li\u003e\n\u003cli\u003eScale Service \u0026amp; Maintenance\u003c\/li\u003e\n\u003cli\u003eIndustrial Weighing Systems\u003c\/li\u003e\n\u003cli\u003eCalibration Preparation\u003c\/li\u003e\n\u003cli\u003eElectronic Scale Diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49096001356032,"sku":null,"price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/1_us_ranger1.png?v=1785343995"},{"product_id":"rice-lake-ranger-3-variable-range-simulator-load-cell-calibration-tester","title":"Rice Lake Ranger 3 Variable Range Simulator Load Cell Calibration Tester","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eRice Lake Ranger 3 Variable Range Simulator\u003c\/strong\u003e\u003cspan\u003e is a professional-grade load cell simulator designed for calibration, testing, and troubleshooting of electronic weighing systems. Built specifically for technicians and scale service professionals, the Ranger 3 provides precise millivolt-per-volt (mV\/V) outputs that simulate load cell signals, allowing indicators and controllers to be tested without connecting an actual scale platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike continuously variable simulators, the Ranger 3 utilizes a fixed rotary switch that provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enine calibrated output levels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-0.5 mV\/V to +4.5 mV\/V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein accurate 0.5 mV\/V increments. These fixed reference points are ideal for verifying indicator performance and performing A\/D calibration procedures. The -0.5 mV\/V setting is commonly used for offset calibration, while the +4.5 mV\/V setting is designed for gain calibration.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeaturing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e350-ohm nominal impedance\u003c\/strong\u003e, the Ranger 3 closely simulates the electrical characteristics of a standard load cell. Its precision design delivers repeatable and reliable test results with nonlinearity of less than 0.02%, making it an excellent tool for service departments, calibration labs, and field technicians.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe compact ABS plastic enclosure weighs less than one pound, making it easy to transport between job sites. Color-coded binding posts accept standard banana plugs or up to 14 AWG wire, allowing quick connection to indicators, transmitters, and weighing electronics.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you're calibrating truck scale indicators, bench scales, floor scales, tank weighing systems, or industrial process weighing equipment, the Ranger 3 delivers a simple and dependable solution for accurate system testing and calibration.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFixed rotary switch with nine calibrated output steps\u003c\/li\u003e\n\u003cli\u003eOutput range from -0.5 mV\/V to +4.5 mV\/V\u003c\/li\u003e\n\u003cli\u003e0.5 mV\/V increments for precise calibration testing\u003c\/li\u003e\n\u003cli\u003eIdeal for A\/D offset and gain calibration of weight indicators\u003c\/li\u003e\n\u003cli\u003e350-ohm nominal impedance simulates a standard load cell\u003c\/li\u003e\n\u003cli\u003eUsed for troubleshooting, testing, and calibrating weighing systems\u003c\/li\u003e\n\u003cli\u003eLightweight ABS plastic enclosure weighs less than 1 lb\u003c\/li\u003e\n\u003cli\u003eBinding posts accept banana plugs or up to 14 AWG wire\u003c\/li\u003e\n\u003cli\u003eNonlinearity less than 0.02%\u003c\/li\u003e\n\u003cli\u003eOne-year limited manufacturer warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRanger 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e68030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eVariable Range Load Cell Simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-0.5 mV\/V to +4.5 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Steps\u003c\/td\u003e\n\u003ctd\u003e9 Fixed Steps (0.5 mV\/V Increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e350 Ohm Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonlinearity\u003c\/td\u003e\n\u003ctd\u003eLess Than 0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eBinding Posts for Banana Plugs or 14 AWG Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e±5 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5\" x 3.5\" x 1.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess Than 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne-Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScale Indicator Calibration\u003c\/li\u003e\n\u003cli\u003eA\/D Offset Calibration\u003c\/li\u003e\n\u003cli\u003eA\/D Gain Calibration\u003c\/li\u003e\n\u003cli\u003eLoad Cell Simulation\u003c\/li\u003e\n\u003cli\u003eIndustrial Scale Troubleshooting\u003c\/li\u003e\n\u003cli\u003eBench Testing Indicators\u003c\/li\u003e\n\u003cli\u003eScale Service \u0026amp; Maintenance\u003c\/li\u003e\n\u003cli\u003eCalibration Laboratories\u003c\/li\u003e\n\u003cli\u003eProcess Weighing Systems\u003c\/li\u003e\n\u003cli\u003eTruck, Floor, and Hopper Scale Testing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49096024785152,"sku":null,"price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/1_us_ranger3.png?v=1785344455"},{"product_id":"rice-lake-ranger-5-variable-range-simulator-load-cell-calibration-tester","title":"Rice Lake Ranger 5 Variable Range Simulator Load Cell Calibration Tester","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eRice Lake Ranger 5 Variable Range Simulator\u003c\/strong\u003e\u003cspan\u003e is a professional-grade load cell simulator designed for advanced troubleshooting, testing, and calibration of electronic weighing systems. Built for scale technicians, service professionals, and calibration laboratories, the Ranger 5 accurately simulates load cell outputs, allowing indicators and weighing electronics to be tested without connecting an actual scale platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike basic simulators, the Ranger 5 combines a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efixed-step rotary switch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision vernier adjustment system\u003c\/strong\u003e. The rotary switch provides nine calibrated output levels ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-0.5 mV\/V to +4.5 mV\/V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein 0.5 mV\/V increments, while the vernier control allows fine adjustments for more precise testing and calibration procedures.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator features a smooth\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10-turn vernier knob with a locking graduated dial\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand selectable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOff, Fine, Medium, and Coarse\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranges. This design allows technicians to perform detailed diagnostics, verify indicator performance, and accurately calibrate A\/D converters for both offset and gain settings. The -0.5 mV\/V setting is commonly used for offset calibration, while the +4.5 mV\/V setting is used for gain calibration.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a nominal impedance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e350 ohms\u003c\/strong\u003e, the Ranger 5 closely replicates the electrical characteristics of a standard load cell. Its high accuracy and nonlinearity of less than 0.02% provide dependable and repeatable test results for demanding industrial weighing applications.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe compact ABS plastic enclosure weighs less than one pound, making it ideal for both bench testing and field service work. Color-coded binding posts accept standard banana plugs or up to 14 AWG wire, enabling quick and convenient connections to indicators, transmitters, and control systems.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhether calibrating truck scale indicators, floor scales, tank weighing systems, hopper scales, or industrial process weighing equipment, the Ranger 5 provides a reliable and accurate solution for advanced scale diagnostics and calibration.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced full-function load cell simulator\u003c\/li\u003e\n\u003cli\u003eFixed rotary switch with nine calibrated output steps\u003c\/li\u003e\n\u003cli\u003eOutput range from -0.5 mV\/V to +4.5 mV\/V\u003c\/li\u003e\n\u003cli\u003ePrecision 10-turn vernier knob with locking graduated dial\u003c\/li\u003e\n\u003cli\u003eFour vernier ranges: Off, Fine, Medium, and Coarse\u003c\/li\u003e\n\u003cli\u003eIdeal for A\/D offset and gain calibration\u003c\/li\u003e\n\u003cli\u003eUsed for testing, troubleshooting, and calibrating digital weight indicators\u003c\/li\u003e\n\u003cli\u003e350-ohm nominal impedance simulates standard load cells\u003c\/li\u003e\n\u003cli\u003eLightweight ABS plastic enclosure weighs less than 1 lb\u003c\/li\u003e\n\u003cli\u003eBinding posts accept banana plugs or 14 AWG wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRanger 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e68031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eVariable Range Load Cell Simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed Output Steps\u003c\/td\u003e\n\u003ctd\u003e-0.5 mV\/V to +4.5 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Increment\u003c\/td\u003e\n\u003ctd\u003e0.5 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVernier Ranges\u003c\/td\u003e\n\u003ctd\u003eOff, Fine, Medium, Coarse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVernier Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 mV\/V, 1.0 mV\/V, and 1.5 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e350 Ohm Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonlinearity\u003c\/td\u003e\n\u003ctd\u003eLess Than 0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eBinding Posts for Banana Plugs or 14 AWG Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e±5 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5\" x 3.5\" x 1.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess Than 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne-Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScale Indicator Calibration\u003c\/li\u003e\n\u003cli\u003eA\/D Offset Calibration\u003c\/li\u003e\n\u003cli\u003eA\/D Gain Calibration\u003c\/li\u003e\n\u003cli\u003eLoad Cell Simulation\u003c\/li\u003e\n\u003cli\u003eIndustrial Scale Troubleshooting\u003c\/li\u003e\n\u003cli\u003eBench Testing Indicators\u003c\/li\u003e\n\u003cli\u003eCalibration Laboratories\u003c\/li\u003e\n\u003cli\u003eService \u0026amp; Maintenance Operations\u003c\/li\u003e\n\u003cli\u003eProcess Weighing Systems\u003c\/li\u003e\n\u003cli\u003eTruck, Floor, Tank, and Hopper Scale Testing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49096057815296,"sku":null,"price":695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/1_us_ranger5.png?v=1785345048"},{"product_id":"rice-lake-ranger-7-high-resolution-load-cell-simulator-calibration-tester","title":"Rice Lake Ranger 7 High Resolution Load Cell Simulator Calibration Tester","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eRice Lake Ranger 7 Variable Range Simulator\u003c\/strong\u003e\u003cspan\u003e is a professional-grade, high-resolution load cell simulator designed for advanced calibration, troubleshooting, and testing of electronic weighing systems. Built for service technicians, calibration laboratories, and industrial weighing professionals, the Ranger 7 provides highly accurate simulated load cell signals for verifying and calibrating digital weight indicators without requiring an actual scale platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eEngineered for applications requiring exceptional resolution, the Ranger 7 features output adjustments down to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.01 mV\/V increments\u003c\/strong\u003e, allowing precise calibration of high-performance indicators and A\/D converters. Its dual Vernier control design enables fine signal adjustment and repeatable test results for demanding calibration procedures.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator includes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eswitchable offset function\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand multiple precision control ranges, making it ideal for testing indicator response, validating calibration parameters, and comparing performance against load cell datasheets. It is particularly useful for diagnosing indicator problems, verifying scale electronics, and performing advanced system troubleshooting.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThree selectable impedance settings allow the Ranger 7 to accurately simulate various weighing system configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX0.5 = 700 Ohms\u003c\/li\u003e\n\u003cli\u003eX1 = 350 Ohms (one standard load cell)\u003c\/li\u003e\n\u003cli\u003eX4 = 87.5 Ohms (four-load-cell platform)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis flexibility makes it suitable for testing both single-load-cell and multi-load-cell weighing systems.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe rugged painted die-cast enclosure provides excellent durability for field service and laboratory environments. Precision gold-plated binding posts accept standard banana plugs or up to 14 AWG wire, ensuring secure and reliable connections during testing.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you're calibrating truck scale indicators, floor scales, tank weighing systems, process control equipment, or industrial weighing instruments, the Ranger 7 delivers the accuracy and reliability required for professional calibration work.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-resolution load cell simulator for precision testing\u003c\/li\u003e\n\u003cli\u003eOutput range from 0 to 3 mV\/V in ultra-fine 0.01 mV\/V steps\u003c\/li\u003e\n\u003cli\u003eSwitchable offset for advanced calibration applications\u003c\/li\u003e\n\u003cli\u003eDual Vernier control system for precise signal adjustment\u003c\/li\u003e\n\u003cli\u003eSimulates single or four-load-cell weighing systems\u003c\/li\u003e\n\u003cli\u003eThree selectable impedance settings: 700Ω, 350Ω, and 87.5Ω\u003c\/li\u003e\n\u003cli\u003eHigh accuracy with ±0.01% + 1µV linearity\u003c\/li\u003e\n\u003cli\u003ePrecision gold-plated binding posts\u003c\/li\u003e\n\u003cli\u003ePainted die-cast enclosure for durability\u003c\/li\u003e\n\u003cli\u003eDesigned for calibration, troubleshooting, and diagnostics of digital weight indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRanger 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e157323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHigh Resolution Load Cell Simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mV\/V Steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVernier Control\u003c\/td\u003e\n\u003ctd\u003eDual Vernier Adjustment System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Function\u003c\/td\u003e\n\u003ctd\u003eSwitchable Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance\u003c\/td\u003e\n\u003ctd\u003eX0.5: 700Ω, X1: 350Ω, X4: 87.5Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±0.01% + 1µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset\u003c\/td\u003e\n\u003ctd\u003e±0.0005 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e5 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003ePrecision Gold-Plated Binding Posts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity\u003c\/td\u003e\n\u003ctd\u003eBanana Plugs or 14 AWG Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePainted Die-Cast Metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eEXC+, EXC-, Offset ON, 0.5 mV\/V, 0.1 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne-Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Weight Indicator Calibration\u003c\/li\u003e\n\u003cli\u003eA\/D Converter Testing\u003c\/li\u003e\n\u003cli\u003eLoad Cell Simulation\u003c\/li\u003e\n\u003cli\u003eScale System Troubleshooting\u003c\/li\u003e\n\u003cli\u003eIndustrial Weighing Diagnostics\u003c\/li\u003e\n\u003cli\u003eBench Testing Indicators\u003c\/li\u003e\n\u003cli\u003eCalibration Laboratories\u003c\/li\u003e\n\u003cli\u003eService \u0026amp; Maintenance Operations\u003c\/li\u003e\n\u003cli\u003eProcess Weighing Systems\u003c\/li\u003e\n\u003cli\u003eTruck, Floor, Tank, and Hopper Scale Testing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49096091795712,"sku":null,"price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/hdimage-1_a4af4ed0-7ec7-404f-8ce3-647fa3a258f9.png?v=1785345597"},{"product_id":"rice-lake-transducer-simulator-4-load-cell-signal-simulator-calibration-tool","title":"Rice Lake Transducer Simulator 4 Load Cell Signal Simulator Calibration Tool","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eRice Lake Transducer Simulator 4\u003c\/strong\u003e\u003cspan\u003e is a professional-grade load cell simulator designed for precision calibration, troubleshooting, and testing of electronic weighing systems. Built for field technicians, calibration laboratories, and industrial maintenance professionals, it accurately replicates a wide variety of load cell conditions, allowing weight indicators and controllers to be tested without connecting an actual scale.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for maximum versatility, the Transducer Simulator 4 supports multiple load cell configurations by simulating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eone, two, three, four, or eight 350-ohm load cells\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo, four, six, eight, or sixteen 700-ohm load cells\u003c\/strong\u003e. This flexibility makes it an excellent diagnostic tool for everything from small bench scales to large industrial weighing systems.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour operating modes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto accommodate virtually any testing requirement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVernier Adjustment\u003c\/li\u003e\n\u003cli\u003eCalibrated Adjustment\u003c\/li\u003e\n\u003cli\u003e0.25 mV\/V Offset\u003c\/li\u003e\n\u003cli\u003e0.50 mV\/V Offset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10-turn wire-wound potentiometer with locking clutch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides smooth, repeatable adjustments, allowing technicians to accurately simulate load cell outputs for indicator calibration, batching systems, and setpoint verification.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBuilt for demanding field environments, the Transducer Simulator 4 features a rugged portable carrying case with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esealed neoprene O-ring lid\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat protects internal components from dust and moisture. The enclosure has been\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecrush tested to 500 pounds\u003c\/strong\u003e, providing outstanding durability during transportation and daily service work.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator delivers excellent measurement stability with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eless than ±0.02% full-scale linearity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand an extremely low temperature coefficient for dependable performance in laboratory and field applications. Binding-post connectors support both loose wires and standard banana plugs for fast, convenient setup.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhether servicing truck scales, floor scales, hopper scales, tank weighing systems, batching equipment, or process control installations, the Rice Lake Transducer Simulator 4 provides reliable, repeatable performance for professional weighing system diagnostics and calibration.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy load cell signal simulator for professional calibration\u003c\/li\u003e\n\u003cli\u003eSimulates one, two, three, four, or eight 350Ω load cells\u003c\/li\u003e\n\u003cli\u003eSimulates two, four, six, eight, or sixteen 700Ω load cells\u003c\/li\u003e\n\u003cli\u003eFour operating modes: Vernier, Calibrated, 0.25 mV\/V Offset, and 0.50 mV\/V Offset\u003c\/li\u003e\n\u003cli\u003ePrecision 10-turn wire-wound potentiometer with locking clutch\u003c\/li\u003e\n\u003cli\u003eSealed carrying case with neoprene O-ring gasket\u003c\/li\u003e\n\u003cli\u003eDustproof enclosure, crush tested to 500 lb\u003c\/li\u003e\n\u003cli\u003eIdeal for setpoint and batching simulation\u003c\/li\u003e\n\u003cli\u003ePortable all-in-one field service design\u003c\/li\u003e\n\u003cli\u003eCompatible with most electronic weight indicators operating from 5–15 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTransducer Simulator 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e22513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eLoad Cell Signal Simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Modes\u003c\/td\u003e\n\u003ctd\u003eVernier, Calibrated, 0.25 mV\/V Offset, 0.50 mV\/V Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment\u003c\/td\u003e\n\u003ctd\u003e10-Turn Wire-Wound Potentiometer with Locking Clutch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Excitation Voltage\u003c\/td\u003e\n\u003ctd\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.02% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003eAbsolute 5 ppm\/°C; Tracking \u0026lt;0.5 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Cell Simulation\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3, 4, or 8 × 350Ω Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Simulation\u003c\/td\u003e\n\u003ctd\u003e2, 4, 6, 8, or 16 × 700Ω Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset\u003c\/td\u003e\n\u003ctd\u003e+0.25 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eBinding Posts for Banana Plugs or Loose Wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eSealed Carrying Case with Neoprene O-Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDurability\u003c\/td\u003e\n\u003ctd\u003eDustproof, Crush Tested to 500 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne-Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLoad Cell Simulation\u003c\/li\u003e\n\u003cli\u003eDigital Weight Indicator Calibration\u003c\/li\u003e\n\u003cli\u003eScale Troubleshooting\u003c\/li\u003e\n\u003cli\u003eBatching System Testing\u003c\/li\u003e\n\u003cli\u003eSetpoint Verification\u003c\/li\u003e\n\u003cli\u003eTruck Scale Diagnostics\u003c\/li\u003e\n\u003cli\u003eFloor Scale Testing\u003c\/li\u003e\n\u003cli\u003eTank \u0026amp; Hopper Scale Calibration\u003c\/li\u003e\n\u003cli\u003eIndustrial Process Weighing\u003c\/li\u003e\n\u003cli\u003eLaboratory Calibration Services\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49096163131648,"sku":null,"price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/1_us_transducersimulator4_open_facingright_a6f9d785-7938-4cd0-91a8-118a48c1a0d0.png?v=1785346256"}],"url":"https:\/\/scaledepot.com\/collections\/simulator.oembed","provider":"Scale Depot","version":"1.0","type":"link"}