{"product_id":"rice-lake-iqube-digital-diagnostic-junction-box-for-1280-enterprise-series","title":"Rice Lake iQUBE³ Digital Diagnostic Junction Box for 1280 Enterprise Series","description":"\u003cp data-section-id=\"1hjuuzt\" data-start=\"252\" data-end=\"313\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Rice Lake iQUBE³ Digital Diagnostic Junction Box is an advanced weighing system management solution engineered for use with the 1280 Enterprise™ Series indicator. Designed for industrial weighing applications, the iQUBE³ provides powerful diagnostics, intelligent load cell monitoring, and scalable networking capabilities for complex weighing systems.\u003c\/p\u003e\n\u003cp data-start=\"1557\" data-end=\"1842\"\u003eEach iQUBE³ CPU board includes four A\/D channels and can network with up to five additional four-channel boards, supporting up to 24 total A\/D channels. This architecture allows users to manage multiple scales simultaneously while maintaining precise system monitoring and performance.\u003c\/p\u003e\n\u003cp data-start=\"1844\" data-end=\"2198\"\u003eBuilt-in diagnostic routines continuously evaluate system health and identify common weighing issues including overload, underload, drift, noise, zero reference errors, and unbalanced load conditions. Integrated bi-color LEDs provide instant visual feedback on load cell status, while the load cell emulator helps maintain operation if a load cell fails.\u003c\/p\u003e\n\u003cp data-start=\"2200\" data-end=\"2397\"\u003eRice Lake's Cal-Match® technology simplifies scale setup by automatically trimming and calibrating the system in a single pass using test weights, reducing installation time and improving accuracy.\u003c\/p\u003e\n\u003cp data-start=\"204\" data-end=\"587\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"2399\" data-end=\"2535\"\u003eIdeal for truck scales, railroad scales, tank weighing systems, hopper scales, and other multi-channel industrial weighing applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"411\" data-end=\"426\" class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"428\" data-end=\"1168\"\u003e\n\u003cli data-section-id=\"1usi7e3\" data-start=\"428\" data-end=\"487\"\u003eDesigned for Rice Lake 1280 Enterprise™ Series indicators\u003c\/li\u003e\n\u003cli data-section-id=\"1tuq0xq\" data-start=\"488\" data-end=\"528\"\u003eFour A\/D channels per iQUBE³ CPU board\u003c\/li\u003e\n\u003cli data-section-id=\"17xrech\" data-start=\"529\" data-end=\"586\"\u003eSupports networking up to five additional iQUBE³ boards\u003c\/li\u003e\n\u003cli data-section-id=\"13x5rz8\" data-start=\"587\" data-end=\"627\"\u003eExpandable up to 24 total A\/D channels\u003c\/li\u003e\n\u003cli data-section-id=\"cmdmvf\" data-start=\"628\" data-end=\"684\"\u003eSupports up to four separate scales plus a Total Scale\u003c\/li\u003e\n\u003cli data-section-id=\"xxdjvo\" data-start=\"685\" data-end=\"738\"\u003eAdvanced diagnostic monitoring for weighing systems\u003c\/li\u003e\n\u003cli data-section-id=\"yw6x45\" data-start=\"739\" data-end=\"824\"\u003eDetects overload, underload, drift, noise, zero reference, and imbalance conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1epndxz\" data-start=\"825\" data-end=\"882\"\u003eBi-color LED indicators provide load cell health status\u003c\/li\u003e\n\u003cli data-section-id=\"186ir1j\" data-start=\"883\" data-end=\"948\"\u003eIntegrated load cell emulator compensates for failed load cells\u003c\/li\u003e\n\u003cli data-section-id=\"15e6umm\" data-start=\"949\" data-end=\"1003\"\u003eCal-Match® automatic trim and calibration technology\u003c\/li\u003e\n\u003cli data-section-id=\"lajckt\" data-start=\"1004\" data-end=\"1034\"\u003eEthernet TCP\/IP connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"1dhva0k\" data-start=\"1035\" data-end=\"1069\"\u003eUSB-C, RS-232\/485 communications\u003c\/li\u003e\n\u003cli data-section-id=\"tjkv8y\" data-start=\"1070\" data-end=\"1112\"\u003eSD card slot for storage and diagnostics\u003c\/li\u003e\n\u003cli data-section-id=\"1j9iqam\" data-start=\"1113\" data-end=\"1168\"\u003eTwo option slots available for expanded functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"2542\" data-end=\"2559\" class=\"PDq2pG_selectionAnchorContainer\"\u003eSpecifications\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2561\" data-end=\"3185\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2561\" data-end=\"2588\"\u003e\n\u003ctr data-start=\"2561\" data-end=\"2588\"\u003e\n\u003cth data-start=\"2561\" data-end=\"2571\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2571\" data-end=\"2588\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2617\" data-end=\"3185\"\u003e\n\u003ctr data-start=\"2617\" data-end=\"2638\"\u003e\n\u003ctd data-start=\"2617\" data-end=\"2625\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2625\" data-end=\"2638\"\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2639\" data-end=\"2657\"\u003e\n\u003ctd data-start=\"2639\" data-end=\"2647\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2647\" data-end=\"2657\"\u003eiQUBE³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2658\" data-end=\"2711\"\u003e\n\u003ctd data-start=\"2658\" data-end=\"2674\" data-col-size=\"sm\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2674\" data-end=\"2711\"\u003e1280 Enterprise™ Series Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2712\" data-end=\"2746\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2727\" data-col-size=\"sm\"\u003eA\/D Channels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2727\" data-end=\"2746\"\u003e4 per CPU Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2747\" data-end=\"2800\"\u003e\n\u003ctd data-start=\"2747\" data-end=\"2775\" data-col-size=\"sm\"\u003eMaximum Network Expansion\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2775\" data-end=\"2800\"\u003eUp to 24 A\/D Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2801\" data-end=\"2856\"\u003e\n\u003ctd data-start=\"2801\" data-end=\"2818\" data-col-size=\"sm\"\u003eCommunications\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2818\" data-end=\"2856\"\u003eEthernet TCP\/IP, RS-232\/485, USB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2857\" data-end=\"2883\"\u003e\n\u003ctd data-start=\"2857\" data-end=\"2867\" data-col-size=\"sm\"\u003eStorage\u003c\/td\u003e\n\u003ctd data-start=\"2867\" data-end=\"2883\" data-col-size=\"md\"\u003eSD Card Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2884\" data-end=\"2911\"\u003e\n\u003ctd data-start=\"2884\" data-end=\"2898\" data-col-size=\"sm\"\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2898\" data-end=\"2911\"\u003eFour DIOs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2912\" data-end=\"3002\"\u003e\n\u003ctd data-start=\"2912\" data-end=\"2926\" data-col-size=\"sm\"\u003eDiagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2926\" data-end=\"3002\"\u003eOverload, Underload, Drift, Noise, Zero Reference, Unbalanced Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3003\" data-end=\"3067\"\u003e\n\u003ctd data-start=\"3003\" data-end=\"3023\" data-col-size=\"sm\"\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3023\" data-end=\"3067\"\u003eBi-Color LED Load Cell Health Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3068\" data-end=\"3118\"\u003e\n\u003ctd data-start=\"3068\" data-end=\"3082\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3082\" data-end=\"3118\"\u003eCal-Match® Automatic Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3119\" data-end=\"3139\"\u003e\n\u003ctd data-start=\"3119\" data-end=\"3134\" data-col-size=\"sm\"\u003eOption Slots\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3134\" data-end=\"3139\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3140\" data-end=\"3185\"\u003e\n\u003ctd data-start=\"3140\" data-end=\"3154\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3154\" data-end=\"3185\"\u003eIndustrial Weighing Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3187\" data-end=\"3190\"\u003e\n\u003ch2 data-section-id=\"qzbkb0\" data-start=\"3192\" data-end=\"3212\"\u003eAvailable Options\u003c\/h2\u003e\n\u003cul data-start=\"3214\" data-end=\"3432\"\u003e\n\u003cli data-section-id=\"1gucr7\" data-start=\"3214\" data-end=\"3241\"\u003eFiber Optic Communication\u003c\/li\u003e\n\u003cli data-section-id=\"1cgamdk\" data-start=\"3242\" data-end=\"3268\"\u003eWireless Ethernet TCP\/IP\u003c\/li\u003e\n\u003cli data-section-id=\"z9eaax\" data-start=\"3269\" data-end=\"3327\"\u003eAnalog Output Board\n\u003cul data-start=\"3293\" data-end=\"3327\"\u003e\n\u003cli data-section-id=\"scrlt1\" data-start=\"3293\" data-end=\"3303\"\u003e0-10 VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1gm50e3\" data-start=\"3306\" data-end=\"3315\"\u003e0-20 mA\u003c\/li\u003e\n\u003cli data-section-id=\"1pu92db\" data-start=\"3318\" data-end=\"3327\"\u003e4-20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10hazfy\" data-start=\"3328\" data-end=\"3349\"\u003eRelay Output Module\u003c\/li\u003e\n\u003cli data-section-id=\"1y8epxd\" data-start=\"3350\" data-end=\"3406\"\u003eSerial Communication Module (RS-232 \/ RS-422 \/ RS-485)\u003c\/li\u003e\n\u003cli data-section-id=\"npksj2\" data-start=\"3407\" data-end=\"3432\"\u003eBridge Resistance Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3434\" data-end=\"3437\"\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"3439\" data-end=\"3454\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"3456\" data-end=\"3607\"\u003e\n\u003cli data-section-id=\"15g3evs\" data-start=\"3456\" data-end=\"3470\"\u003eTruck Scales\u003c\/li\u003e\n\u003cli data-section-id=\"o4jwh9\" data-start=\"3471\" data-end=\"3488\"\u003eRailroad Scales\u003c\/li\u003e\n\u003cli data-section-id=\"1w454oq\" data-start=\"3489\" data-end=\"3512\"\u003eTank Weighing Systems\u003c\/li\u003e\n\u003cli data-section-id=\"flj6mr\" data-start=\"3513\" data-end=\"3528\"\u003eHopper Scales\u003c\/li\u003e\n\u003cli data-section-id=\"vbj9sn\" data-start=\"3529\" data-end=\"3547\"\u003eProcess Weighing\u003c\/li\u003e\n\u003cli data-section-id=\"119lckb\" data-start=\"3548\" data-end=\"3575\"\u003eMulti-Scale Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1kh1j9i\" data-start=\"3576\" data-end=\"3607\"\u003eIndustrial Automation Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49081806618880,"sku":"PS-iQUBE","price":1449.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/1_iqube3_1280_leftface_lr.png?v=1785167795","url":"https:\/\/scaledepot.com\/products\/rice-lake-iqube-digital-diagnostic-junction-box-for-1280-enterprise-series","provider":"Scale Depot","version":"1.0","type":"link"}