{"product_id":"rice-lake-ranger-7-high-resolution-load-cell-simulator-calibration-tester","title":"Rice Lake Ranger 7 High Resolution Load Cell Simulator Calibration Tester","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eRice Lake Ranger 7 Variable Range Simulator\u003c\/strong\u003e\u003cspan\u003e is a professional-grade, high-resolution load cell simulator designed for advanced calibration, troubleshooting, and testing of electronic weighing systems. Built for service technicians, calibration laboratories, and industrial weighing professionals, the Ranger 7 provides highly accurate simulated load cell signals for verifying and calibrating digital weight indicators without requiring an actual scale platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eEngineered for applications requiring exceptional resolution, the Ranger 7 features output adjustments down to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.01 mV\/V increments\u003c\/strong\u003e, allowing precise calibration of high-performance indicators and A\/D converters. Its dual Vernier control design enables fine signal adjustment and repeatable test results for demanding calibration procedures.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator includes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eswitchable offset function\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand multiple precision control ranges, making it ideal for testing indicator response, validating calibration parameters, and comparing performance against load cell datasheets. It is particularly useful for diagnosing indicator problems, verifying scale electronics, and performing advanced system troubleshooting.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThree selectable impedance settings allow the Ranger 7 to accurately simulate various weighing system configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX0.5 = 700 Ohms\u003c\/li\u003e\n\u003cli\u003eX1 = 350 Ohms (one standard load cell)\u003c\/li\u003e\n\u003cli\u003eX4 = 87.5 Ohms (four-load-cell platform)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis flexibility makes it suitable for testing both single-load-cell and multi-load-cell weighing systems.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe rugged painted die-cast enclosure provides excellent durability for field service and laboratory environments. Precision gold-plated binding posts accept standard banana plugs or up to 14 AWG wire, ensuring secure and reliable connections during testing.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you're calibrating truck scale indicators, floor scales, tank weighing systems, process control equipment, or industrial weighing instruments, the Ranger 7 delivers the accuracy and reliability required for professional calibration work.\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-resolution load cell simulator for precision testing\u003c\/li\u003e\n\u003cli\u003eOutput range from 0 to 3 mV\/V in ultra-fine 0.01 mV\/V steps\u003c\/li\u003e\n\u003cli\u003eSwitchable offset for advanced calibration applications\u003c\/li\u003e\n\u003cli\u003eDual Vernier control system for precise signal adjustment\u003c\/li\u003e\n\u003cli\u003eSimulates single or four-load-cell weighing systems\u003c\/li\u003e\n\u003cli\u003eThree selectable impedance settings: 700Ω, 350Ω, and 87.5Ω\u003c\/li\u003e\n\u003cli\u003eHigh accuracy with ±0.01% + 1µV linearity\u003c\/li\u003e\n\u003cli\u003ePrecision gold-plated binding posts\u003c\/li\u003e\n\u003cli\u003ePainted die-cast enclosure for durability\u003c\/li\u003e\n\u003cli\u003eDesigned for calibration, troubleshooting, and diagnostics of digital weight indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRice Lake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRanger 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e157323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHigh Resolution Load Cell Simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mV\/V Steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVernier Control\u003c\/td\u003e\n\u003ctd\u003eDual Vernier Adjustment System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Function\u003c\/td\u003e\n\u003ctd\u003eSwitchable Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance\u003c\/td\u003e\n\u003ctd\u003eX0.5: 700Ω, X1: 350Ω, X4: 87.5Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±0.01% + 1µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset\u003c\/td\u003e\n\u003ctd\u003e±0.0005 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e5 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003ePrecision Gold-Plated Binding Posts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity\u003c\/td\u003e\n\u003ctd\u003eBanana Plugs or 14 AWG Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePainted Die-Cast Metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eEXC+, EXC-, Offset ON, 0.5 mV\/V, 0.1 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne-Year Limited Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Weight Indicator Calibration\u003c\/li\u003e\n\u003cli\u003eA\/D Converter Testing\u003c\/li\u003e\n\u003cli\u003eLoad Cell Simulation\u003c\/li\u003e\n\u003cli\u003eScale System Troubleshooting\u003c\/li\u003e\n\u003cli\u003eIndustrial Weighing Diagnostics\u003c\/li\u003e\n\u003cli\u003eBench Testing Indicators\u003c\/li\u003e\n\u003cli\u003eCalibration Laboratories\u003c\/li\u003e\n\u003cli\u003eService \u0026amp; Maintenance Operations\u003c\/li\u003e\n\u003cli\u003eProcess Weighing Systems\u003c\/li\u003e\n\u003cli\u003eTruck, Floor, Tank, and Hopper Scale Testing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rice Lake","offers":[{"title":"Default Title","offer_id":49096091795712,"sku":null,"price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/4088\/6784\/files\/hdimage-1_a4af4ed0-7ec7-404f-8ce3-647fa3a258f9.png?v=1785345597","url":"https:\/\/scaledepot.com\/products\/rice-lake-ranger-7-high-resolution-load-cell-simulator-calibration-tester","provider":"Scale Depot","version":"1.0","type":"link"}