Rice Lake 882IS Plus Intrinsically Safe Digital Weight Indicator IP66
The Rice Lake 882IS® and 882IS Plus Intrinsically Safe Digital Weight Indicators are purpose-built weighing solutions designed for hazardous and explosive environments where safety, reliability, and weighing accuracy are critical. Certified for use in Class I, II, and III hazardous locations, the 882IS Series allows operators to perform weighing operations safely in areas where combustible gases, vapors, dust, or fibers may be present. These indicators are ideal for chemical processing plants, petroleum facilities, pharmaceutical manufacturing, paint production, grain handling operations, mining environments, and other hazardous industrial applications.
Designed with intrinsic safety at its core, the 882IS Series eliminates the need for explosion-proof enclosures while maintaining full operational capability in classified environments. The indicators are Factory Mutual (FM/cFMus), ATEX, IECEx, NTEP, Measurement Canada, and OIML approved, making them suitable for legal-for-trade and industrial weighing applications worldwide. The T4 temperature rating ensures safe operation in potentially explosive atmospheres while meeting stringent international safety standards.
The 882IS utilizes a bright seven-digit LCD display with a white LED backlight that provides excellent visibility in low-light industrial environments. The standard 882IS model features dedicated weighing function keys, while the 882IS Plus adds a full numeric keypad for enhanced data entry, transaction processing, and operational flexibility. A battery life indicator and power-saving mode help maximize runtime in portable applications.
Constructed with a rugged stainless-steel IP66 enclosure, the indicator is designed to withstand harsh industrial environments while protecting internal electronics from dust, moisture, and contamination. The durable enclosure and integrated tilt stand provide reliable performance in demanding production areas and hazardous locations where equipment durability is essential.
For enhanced connectivity, the 882IS Series features dual fiber-optic communication ports capable of transmitting data up to 500 feet (152 meters). These electrically isolated communications provide safe data transfer between hazardous and safe areas without compromising intrinsic safety requirements. Optional I/O modules further expand functionality with Ethernet TCP/IP, serial communications, analog outputs, industrial fieldbus protocols, and additional control capabilities.
The indicator supports up to four 350-ohm or eight 700-ohm load cells and provides accurate weighing performance with an internal resolution of 1,000,000 counts and update rates up to 60 updates per second. Advanced weighing functions include gross, net, tare, accumulation, configurable local/remote operation, automatic zero tracking, and temperature compensation for consistent accuracy.
An optional FM-approved rechargeable battery pack provides portable operation for remote or movable weighing applications. Depending on load cell configuration, the battery can provide up to 100 hours of operation on a single charge, making it ideal for field installations and mobile weighing systems.
Whether installed on floor scales, tank weighing systems, drum filling stations, hazardous material processing lines, or industrial process weighing systems, the Rice Lake 882IS Series delivers dependable intrinsically safe weighing performance without sacrificing connectivity, functionality, or ease of use.
Specifications
| Feature | Specification |
|---|---|
| Brand | Rice Lake |
| Model | 882IS® / 882IS Plus |
| Product Type | Intrinsically Safe Digital Weight Indicator |
| Display | Seven-Digit LCD with White LED Backlight |
| Display Resolution | 10,000 Divisions |
| Internal Resolution | 1,000,000 Counts |
| Keypad | 5-Key (882IS), Full Numeric Keypad (882IS Plus) |
| Load Cell Capacity | 4 × 350Ω or 8 × 700Ω |
| Excitation Voltage | 3.0–4.6 VDC |
| Update Rate | 60 Updates Per Second |
| Communication | Dual Fiber Optic Ports |
| Maximum Communication Distance | 500 ft (152 m) |
| Enclosure Material | Stainless Steel |
| Environmental Rating | IP66 |
| Power Input | 5.8–7.9 VDC |
| Optional Battery Runtime | Up to 100 Hours |
| Operating Temperature | 14°F to 104°F (-10°C to 40°C) |
| Weight | 6.1 lb (2.8 kg) |
| Warranty | One-Year Limited Warranty |
Standard Features
✔ Intrinsically safe design for hazardous locations
✔ FM/cFMus, ATEX, and IECEx approved
✔ Bright LCD display with white LED backlight
✔ Stainless steel IP66 enclosure
✔ Dual fiber-optic communication ports
✔ Communication distance up to 500 ft
✔ T4 temperature rating
✔ Battery life monitoring icon
✔ Configurable local/remote operation
✔ Automatic zero and span compensation
✔ Optional Ethernet and serial communication modules
✔ Optional analog output and industrial protocol cards
✔ Rechargeable battery option available
✔ Full numeric keypad on 882IS Plus model
| Type: | |
|---|---|
| Vendor: | |
| Model: |
PS-195091, PS-185288, PS-194231, PS-196273, PS-185290, PS-194235, PS-194232 |