Rice Lake Ranger 5 Variable Range Simulator Load Cell Calibration Tester
The Rice Lake Ranger 5 Variable Range Simulator is a professional-grade load cell simulator designed for advanced troubleshooting, testing, and calibration of electronic weighing systems. Built for scale technicians, service professionals, and calibration laboratories, the Ranger 5 accurately simulates load cell outputs, allowing indicators and weighing electronics to be tested without connecting an actual scale platform.
Unlike basic simulators, the Ranger 5 combines a fixed-step rotary switch with a precision vernier adjustment system. The rotary switch provides nine calibrated output levels ranging from -0.5 mV/V to +4.5 mV/V in 0.5 mV/V increments, while the vernier control allows fine adjustments for more precise testing and calibration procedures.
The simulator features a smooth 10-turn vernier knob with a locking graduated dial and selectable Off, Fine, Medium, and Coarse ranges. This design allows technicians to perform detailed diagnostics, verify indicator performance, and accurately calibrate A/D converters for both offset and gain settings. The -0.5 mV/V setting is commonly used for offset calibration, while the +4.5 mV/V setting is used for gain calibration.
With a nominal impedance of 350 ohms, the Ranger 5 closely replicates the electrical characteristics of a standard load cell. Its high accuracy and nonlinearity of less than 0.02% provide dependable and repeatable test results for demanding industrial weighing applications.
The compact ABS plastic enclosure weighs less than one pound, making it ideal for both bench testing and field service work. Color-coded binding posts accept standard banana plugs or up to 14 AWG wire, enabling quick and convenient connections to indicators, transmitters, and control systems.
Whether calibrating truck scale indicators, floor scales, tank weighing systems, hopper scales, or industrial process weighing equipment, the Ranger 5 provides a reliable and accurate solution for advanced scale diagnostics and calibration.
Key Features
- Advanced full-function load cell simulator
- Fixed rotary switch with nine calibrated output steps
- Output range from -0.5 mV/V to +4.5 mV/V
- Precision 10-turn vernier knob with locking graduated dial
- Four vernier ranges: Off, Fine, Medium, and Coarse
- Ideal for A/D offset and gain calibration
- Used for testing, troubleshooting, and calibrating digital weight indicators
- 350-ohm nominal impedance simulates standard load cells
- Lightweight ABS plastic enclosure weighs less than 1 lb
- Binding posts accept banana plugs or 14 AWG wire
Specifications
| Feature | Specification |
|---|---|
| Brand | Rice Lake |
| Model | Ranger 5 |
| Part Number | 68031 |
| Type | Variable Range Load Cell Simulator |
| Fixed Output Steps | -0.5 mV/V to +4.5 mV/V |
| Step Increment | 0.5 mV/V |
| Vernier Ranges | Off, Fine, Medium, Coarse |
| Vernier Adjustment | Up to 0.5 mV/V, 1.0 mV/V, and 1.5 mV/V |
| Impedance | 350 Ohm Nominal |
| Nonlinearity | Less Than 0.02% |
| Connectors | Binding Posts for Banana Plugs or 14 AWG Wire |
| Temperature Coefficient | ±5 ppm/°C |
| Enclosure Material | ABS Plastic |
| Dimensions | 4.5" x 3.5" x 1.25" |
| Weight | Less Than 1 lb |
| Warranty | One-Year Limited Warranty |
Applications
- Scale Indicator Calibration
- A/D Offset Calibration
- A/D Gain Calibration
- Load Cell Simulation
- Industrial Scale Troubleshooting
- Bench Testing Indicators
- Calibration Laboratories
- Service & Maintenance Operations
- Process Weighing Systems
- Truck, Floor, Tank, and Hopper Scale Testing
| Type: | |
|---|---|
| Vendor: |